best selling
-
SHENLER DOUBLE POLE RELAY BASE WITH LEVER
Plastic marker clip
-DIN rail mounting -
Dinrail 24/7 Timer Switch – 16A 36mm-width
Weekly programmable digital timer with dinrail installation and advanced one week prior pre-setting.
Easy to control once installed with a 24 hour cycle and LCD display.
High current rating making this timer suitable for commercial use with a lithium battery reserve of 3 years when power is cut off.Rated voltage: 240VAC
Frequency: 50/60Hz
Power consumption: 1W
Cycle: 24hours -
TANZINI TCG Series Main Isolater 1Pole 100A
Rated Current: 100A
Rated Voltage: 230/400Vac 50Hz
Pole: 1
Degree of protection: IP20
Width: 18mm
Height: 84mm
Depth: 77mm -
TANZINI MCB 1Pole 10A Type-C TCG Series
Rated Current: 10A
Rated Voltage: 230/400Vac 50Hz
Pole: 1P
Type C
Ic=Inc=6kAComply with AS/NZS 60898
-
TANZINI MCB 1Pole 6A Type-C TCG Series
Rated Current: 6A
Rated Voltage: 230/400Vac 50Hz
Pole: 1P
Type C
Ic=Inc=6kAComply with AS/NZS 60898
-
LEGRAND ISOLATING SWITCH 1P 63A
Isolating switches DX3-IS – from 16 A to 125 A
Double break contactsfor more product information, please click https://www.legrand.co.nz
Product characteristics
Isolating switches – Grey handle
AC 22 A
Can be equipped with 1 DX3 signalling auxiliary
1P – 250 V~
Compatible with prong-type and fork type supply busbars
Nominal rating In : 63 A
Number of modules : 1 -
TANZINI TCG Series RCD 2Pole 63A
Rated Current: 63A
Rated Voltage: 230Vac 50Hz
Pole: 1P+N
In=30mA
Ic=Inc=6kAWidth:36mm
Height: 84mm
Depth: 69mmComply with AS/NZS 61008
-
CHINT AC Contactor 4 x N/O 4Pole 25A
Din Mount 4P 25 amp Contactor 240V 4 x N/O
-
HRC Fuse 16A offset
High rupturing capacity fuse is able to carry heavy current in a short circuit for a period of time.
The fuse does not blow off if the fault is removed within this period of time , otherwise it may blow off or melt.
HRC fuse does not require maintenance and can clear high and low current faults. -
Digital Check Meter- 40A 36mm-width Single phase
Single phase 36mm-width Digital power check meter.
Reliable method for checking how much power is being consumed.
Complies with IEC62053-21 standard AND IP51 rated for protection against penetration of dust and water.Width: 36mm
Input voltage: 220-250AC
Rated current: 40A
Dinrail mounting -
EMERGENCY LIGHTING CONTROLLER 230V
ENYA series
Timer for automatic test of emergency lights
Integrated test key
1 change over contact
Width 17.5mm
Installation designTechnical dataWs Single shot leading edge with control contact
Time ranges
Time range reversible between
10min, 30min, 60min, 90min, 2h and 3h
IP rating IP20
Tightening torque: max. 1Nm
Terminal capacity:
1 x 0.5 to 2.5mm² with/without multicore cable end
1 x 4mm² without multicore cable end
2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² flexible without multicore cable end
5. Input circuit
Supply voltage: 230V AC
Terminals: L-N
Tolerance: -15% to +10%
Rated frequency: 48 to 63Hz
Rated consumption: 2VA (1.0W)
Duty cycle: 100%
Reset time: 500ms
Ripple and noise at DC: –
Drop out voltage: >30% of supply voltage
Overvoltage category: III (in accordance with IEC 60664-1)
Rated surge voltage: 4kV -
CHINT AC Contactor 2 x N/O 2Pole 20A
Din Mount 2P 20 amp Contactor 240V 2 x N/O
-
Dinrail 24/7 Timer Switch – 1 pole 16A
Programmable analogue timer with the option to customise the settings.
Easy to control once installed with a 24 hour cycle and a low power consumption.
High current rating making this timer suitable for commercial use with a 15 minute minimum interval and 3 day reserve if power cuts off.Rated voltage: 240VAC
Frequency: 50/60Hz
Power consumption: 1W
Cycle: 24hours -
TANZINI TCG Series RCD 2Pole 40A
Rated Current: 40A
Rated Voltage: 230Vac 50Hz
Pole: 1P+N
In=30mA
Ic=Inc=6kAWidth:36mm
Height: 84mm
Depth: 69mmComply with AS/NZS 61008
High-quality controlgear for efficient regulation and management of electrical devices.
Ensures precise control, safety, and reliability in automation and power systems